What the Product Contains

This cartridge contains 9.5 oz of ready-to-use two-component AC200+ acrylic injection adhesive.

Product Overview

DeWalt AC200+ Concrete Anchor Adhesive is a high-strength acrylic injection system specifically designed for demanding construction professionals. This two-component acrylic anchor system provides a reliable chemical anchoring solution for securely fixing threaded rods and rebar in hardened concrete.

This structural concrete adhesive stands out for its unique ability to be installed at temperatures as low as -10°C, a crucial advantage for construction sites in Quebec and across Canada. The AC200+ concrete injection adhesive has been rigorously evaluated and certified for its freeze-thaw cycle performance, guaranteeing exceptional durability in our harsh climate. The system meets ACI 355.4 and ICC-ES AC308 standards for structural applications in cracked and uncracked concrete.

The fast-setting formula allows for faster curing compared to traditional epoxy systems, thus increasing on-site productivity. The adhesive works effectively in dry, damp, or even water-saturated concrete, offering unmatched versatility. The dual-compartment cartridge with a static mixing nozzle ensures consistent and precise mixing of the components every time.

Key Points :

  • Installation possible down to -10°C for Quebec winter construction sites
  • Certified freeze-thaw cycle performance for Canadian climate durability
  • Fast setting for accelerated processing vs epoxy
  • Works in dry concrete, wet concrete, or water-filled holes
  • Compliant with 2021 IBC/IRC building codes for structural applications

The AC200+ is ideal for anchoring heavy equipment, installing structural supports, securing guardrails, and connecting rebar after installation. It comes with a 9.5 oz Quickshot cartridge compatible with standard application guns. Free shipping across Canada on orders of $150 or more.

Use

Ideal for structural and commercial installations requiring high-strength anchors:

  • Residential and commercial construction: fixing beams, columns, structural wall supports
  • Industrial equipment installation: heavy machinery, HVAC systems, manufacturing equipment
  • Infrastructure projects: guardrails, ramps, safety barriers, signage supports
  • Renovation and reinforcement: rebar connections, structural concrete repairs
  • Mechanical and electrical installation: conduit supports, tank anchors, platform fixings
  • Exterior projects in Quebec: commercial terraces, freeze-thaw resistant outdoor structures
  • Winter construction sites: urgent installations in cold temperatures down to -10°C
  • Marine and wet applications: docks, structures exposed to water, saturated holes

Technical Specifications

  • Product type : Two-component acrylic injection adhesive
  • Cartridge size : 9.5 oz (280 ml) - Quickshot
  • Model : AC200+
  • Brand : DeWalt
  • SKU : PFC1271050
  • Composition : Two-component hybrid acrylic
  • Applications : Threaded rods, reinforcing bars, anchor bolts
  • Base materials : Cracked/uncracked concrete, solid masonry, mortar-filled concrete block
  • Installation temperature : -10°C to 40°C (14°F to 104°F)
  • Operating temperature : -40°C to 80°C long term / 160°C short term
  • Setting time : Varies depending on base temperature (see manufacturer's table)
  • Concrete strength : 2,500 to 8,000 PSI
  • Installation conditions : Dry concrete, damp concrete, water-filled holes
  • Certifications : ICC-ES ESR-4027, ACI 355.4, ASTM E488, ICC-ES AC308
  • Code compliance : IBC/IRC 2021, 2018, 2015, 2012
  • Seismic performance : Qualified for seismic loads and wind
  • Freeze-thaw resistance : Evaluated and approved through freeze-thaw cycles
  • Shelf life : 18 months between 0°C and 35°C
  • DeWalt Manufacturer's Warranty : Limited 3 years
  • Country of manufacture : United States
  • Package contents : 1 x 9.5 oz dual cartridge (mixing nozzle sold separately)

Product Set

Contents of the DeWalt AC200+ Anchoring System

The complete AC200+ chemical anchoring system is the professional solution for your structural projects. This individual cartridge forms the core of the injection system, which you will complete with the appropriate accessories.

Included in your order:

1x AC200+ Cartridge 9.5 oz (280 ml)

High-performance, two-component acrylic injection adhesive in a dual-compartment cartridge. Each cartridge provides enough adhesive for multiple anchors, depending on hole diameter and depth. Fast-curing acrylic formulation approved for structural applications in concrete and masonry. Compatible with standard 10 oz. application guns.

Advantages of the DeWalt AC200+ System

Economy and operational efficiency

The 9.5 oz format offers excellent value for medium-sized projects requiring multiple structural anchors. The cartridge allows for multiple uses with additional mixing nozzles, reducing waste compared to single-use capsules.

Superior Quebec climate performance

Unlike standard epoxies, AC200+ performs effectively down to -10°C and withstands the repeated freeze-thaw cycles typical of Quebec's climate. This unique capability eliminates winter work stoppages and ensures the long-term durability of anchors.

Unmatched installation versatility

Install with confidence in dry, damp, or fully waterlogged concrete without any loss of performance. This flexibility eliminates drying times and allows work to progress in a variety of conditions, significantly increasing productivity.

Regulatory compliance assured

Complete system certified ICC-ES and compliant with current Canadian building codes. Full technical documentation available for project inspections and approvals, eliminating the risk of non-compliance.

Recommended Additional Accessories

Maximize your investment with these essential accessories:

SDS-Plus Carbide Drill BitsPrecision drill bits suitable for impact drilling, guaranteeing diameters that meet the requirements of chemical anchors. Wide range of sizes available. Sold separately.


10 oz Manual Applicator GunA robust tool designed for effortless dispensing of 10 oz cartridges. The optimized thrust ratio facilitates the injection of high-viscosity adhesives. Sold separately.


Static Mixing NozzleCompatible with AC200+ adhesive. It ensures a perfectly uniform mix of components. A new nozzle must be used each time you resume work. Sold separately.

Care and Usage

First Use

Preparation and activation of your AC200+ anchoring adhesive:

1. Control the cartridge temperature

Ensure the cartridge is stored between 5°C and 40°C before use. For installations in base temperatures between -10°C and -5°C, precondition the cartridge at a minimum of 10°C for 2 hours.

2. Install the mixing nozzle

Remove the protective cap from the cartridge. Screw a new static mixing nozzle firmly onto the tip of the dual cartridge. Always use a new nozzle for each work session.

3. Purge and prime the system

Insert the cartridge into the applicator gun. Squeeze the first two inches of adhesive onto a scrap surface to remove air and ensure thorough mixing. The adhesive should come out a uniform gray once properly mixed.

4. Check the hole preparation

Before injection, confirm that all holes are drilled to the correct diameter, cleaned with a wire brush, and blown out with an oil-free air pump. Clean holes are critical for maximum adhesion.

Regular Maintenance

To maximize the lifespan and performance of your cartridges:

After each use:

Immediately release the pressure on the gun after injection to stop the adhesive flow. Wipe any excess adhesive from the cartridge nozzle with a clean cloth. Leave the mixing nozzle installed on the cartridge to protect the residual adhesive from air and moisture until the next use.

Mixing nozzle management:

Always replace the mixing nozzle if the cartridge is left inactive for more than 30 minutes or between work sessions. A partially hardened nozzle compromises the mixing ratio and reduces anchoring performance. Always keep spare nozzles on the job site.

Storage between uses:

Store partially used cartridges upright in their original packaging. Maintain the storage temperature between 0°C and 35°C. Inspect the cartridge before reuse and replace it if there is visible hardening or separation of components.

Cleaning and Maintenance

Cleaning of application equipment:

Applicator gunAfter each use, disassemble and clean the pressure mechanism with a dry cloth. Remove any hardened adhesive residue from the cartridge holder. Lightly lubricate the piston threaded rod with light oil monthly.

Used mixing nozzlesDo not attempt to clean or reuse the nozzles. The acrylic adhesive hardens rapidly and cleaning is impossible. Dispose of used nozzles in your regular waste after they have fully hardened.

Auxiliary toolsClean the metal hole cleaning brushes with a degreasing solvent after use. Purge and dry the air pump to prevent concrete dust from accumulating in the mechanism.

Precautions for Use

For your safety and optimal performance:

Never exceed the installation temperature limits of -10°C to 40°C, as this directly affects the setting time and final strength of the anchor. Installations outside this range can lead to structural failure.

Never use the AC200+ cartridge with incompatible or damaged mixing nozzles. Improper mixing of the components results in uncured adhesive and anchors that do not meet certified load ratings.

Never install in frozen, frosted, or exposed concrete, as adhesion will be severely compromised. If necessary, warm the anchoring area above -5°C before installation.

Never exceed the expiry date indicated on the cartridge. Expired adhesive may exhibit component separation, abnormal viscosity, or unpredictable setting times, compromising structural integrity.

Always wear appropriate personal protective equipment, including safety glasses and chemical-resistant gloves, when handling and injecting acrylic adhesive. Ensure adequate ventilation of the work area.

Storage Tips

Short-term storage (less than 3 months):

Store new and partially used cartridges upright in their original protective packaging. Maintain an ambient temperature between 5°C and 30°C for optimal lifespan. Avoid direct sunlight or heat sources, which can accelerate premature aging of the components.

Long-term storage (3 months and more):

Store in a temperate location between 0°C and 25°C with controlled relative humidity below 80%. Check the cartridge seals monthly for any visible separation of components. Use the oldest cartridges first, following the FIFO (First In, First Out) principle. Maximum shelf life is 18 months from the date of manufacture.

Winter storage in Quebec:

Never store cartridges in unheated vehicles or outdoor trailers during Quebec winters. Freezing the components will irreversibly damage their adhesive properties. If temporary cold storage is unavoidable, gradually warm the cartridges to room temperature for at least 12 hours before use, without ever using direct or accelerated heating.

Warranty

Polar Industrial Equipment Warranty Cover

Our store offers a 30-day satisfaction guarantee allowing you to try the AC200+ system risk-free on your construction sites.

DeWalt Warranty Cover

Warranty period:

3-year limited manufacturer's warranty from DeWalt

DeWalt 90-Day Satisfaction Guarantee

Period beginning on the date of purchase as proven by invoice

What Is Covered

The DeWalt limited warranty covers:

Manufacturing defectsAny defect resulting from formulation errors, contamination during production, or non-compliance with published technical specifications. DeWalt will replace defective cartridges free of charge.

Material defectsCartridges exhibiting premature leakage, abnormal component separation, or hardening in sealed containers before the expiration date. Exchange or refund at DeWalt's discretion.

Non-compliant performanceAdhesive does not meet ICC-ES certified strength values ​​when installed according to recommended procedures in concrete to minimum specifications. Requires technical documentation and tensile testing.

What DeWalt will do:

Free replacement of confirmed defective products

Refund of the purchase price if replacement is impossible

Technical support for resolving application problems

Warranty Exclusions

The warranty does NOT cover:

Normal wear and expected lifespan: Gradual hardening of the product after the expiry date of 18 months, natural degradation during prolonged storage beyond recommendations or exposure to extreme conditions.

Damage due to improper installation: Defective anchors resulting from poorly cleaned holes, concrete below the minimum required strength of 2,500 PSI, insufficient anchoring depth or failure to respect setting time before loading.

Improper storage: Cartridges exposed to repeated freeze-thaw cycles, excessive heat above 35°C, prolonged exposure to direct UV rays or storage in a horizontal position causing component separation.

Extreme installation conditions: Installations in frozen concrete, base temperatures below -10°C or above 40°C, complete permanent immersion after installation or unapproved applications in untested materials.

Physical damage and contamination: Cartridges that are punctured, cracked, dropped from a height, contaminated by solvents or other chemicals, or reused mixing nozzles that compromise the ratio.

Product modification: Mixing with unapproved additives, dilution of components, or attempts at homemade reformulation of the system.

Complaint Procedure

How to file a claim in 4 steps:

Step 1: Documentation to prepare

Keep your original Polar Industrial Equipment purchase invoice showing the date, model number, and quantity. Photograph the defective cartridges, showing the lot number and expiration date. Document the problem with clear photos or videos. Gather all relevant technical documentation.

Step 2: Initial contact according to the timeframe

For returns within the first 30 days - Polar Industrial Equipment Customer Service:

Telephone: 1-800-567-3206

E-mail :info@equipementpolar.com

Address: 3425 Wilfrid-Hamel Boulevard, Quebec

Hours: Monday-Friday 8am-5pm

For DeWalt manufacturer warranty claims (after 30 days):

Visit a DeWalt Canada service center or contact them through their official website to locate the nearest authorized center. Technical documentation and lot numbers are required.

Step 3: Evaluation and authorization

Our team or DeWalt will review your claim within 2-3 business days. A return authorization number will be issued if the claim is accepted. Never return products without prior authorization.

Step 4: Return and processing

Securely pack the defective cartridges in their original packaging if possible. Include a copy of the invoice, authorization number, and a detailed description of the problem. Ship to the address provided during authorization. Replacement or refund will be processed within 7-10 business days after receipt and inspection.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

Our answers to your questions about DeWalt AC200+ Adhesive

At what temperature can I install DeWalt AC200+?

The AC200+ anchoring adhesive operates within an exceptional temperature range of -10°C to 40°C, which sets it apart from traditional epoxy systems limited to a minimum of 5°C. This unique capability allows winter installations on Quebec jobsites without work stoppages.

For base temperatures between -10°C and -5°C, preheat the cartridge to at least 10°C for 2 hours before use. Cure time will be longer in cold weather: up to 24 hours at -10°C compared to 45 minutes at 20°C.

Always consult the manufacturer’s cure time table before applying load to the anchors to ensure full curing and nominal strength.

What is the difference between DeWalt AC200+ and epoxy adhesives like Hilti?

The main differences involve chemical composition and application conditions:

Composition:

  • AC200+: Hybrid acrylic with fast cure, automatically mixed in a static nozzle
  • Standard epoxy: Epoxy-amine resin with critical, more sensitive mixing

Installation temperature range:

  • AC200+: -10°C to 40°C
  • Typical epoxy: 5°C to 40°C

Wet conditions:

  • AC200+: Works in water-saturated holes without performance loss
  • Epoxy: Requires dry or slightly damp holes only

Cure time and productivity:

  • AC200+: Fast curing, accelerated load application
  • Epoxy: Generally slower, longer waiting times

Applications:

Both are suitable for certified structural applications, but AC200+ provides superior flexibility for Quebec jobsites with variable temperature and humidity conditions.

Does AC200+ work in damp concrete or water-filled holes?

Yes, absolutely. AC200+ is specifically approved for installation in three conditions:

  • Standard dry concrete
  • Wet or saturated concrete
  • Holes completely filled with water

This unique versatility eliminates drying delays and allows work to continue in new foundations, exterior repairs in the rain, or areas with high groundwater.

Important: even in saturated conditions, always thoroughly clean holes with a wire brush and air pump to remove debris and concrete laitance. Cleanliness remains critical for maximum adhesion despite the presence of water.

For optimal performance in saturated holes, inject adhesive from the bottom up in a continuous motion to progressively push water ahead of the adhesive front.

What is included with the AC200+ cartridge and what else do I need?

Your purchase includes:

  • 1 dual 9.5 oz (280 ml) cartridge of AC200+ acrylic adhesive

Essential separately sold accessories:

  • DeWalt PFC1641600 static mixing nozzles (pack of 10): One new nozzle required per work session
  • Standard 10 oz manual dispensing gun: Applies adhesive smoothly into holes

Hole preparation equipment:

  • Carbide percussion drill bit of appropriate diameter
  • Wire brush for hole cleaning
  • Oil-free air pump for debris blowing
  • Threaded rods or rebar meeting manufacturer specifications

Refer to our Complementary Accessories section for complete system ordering. Our team can guide you in selecting the optimal setup based on your specific application.

How long should I wait before loading the anchor?

Cure time varies significantly depending on base concrete temperature:

  • At 20°C: 45 minutes
  • At 10°C: 2 hours
  • At 0°C: 6 hours
  • At -5°C: 12 hours
  • At -10°C: 24 hours

These times represent the minimum delay before applying full nominal loads. For partial loads or light handling, consult the manufacturer’s detailed technical tables.

Always measure the actual concrete surface temperature with an infrared thermometer—not the ambient air temperature. Mass concrete retains temperatures different from the surrounding air.

For critical projects or seismic loads, wait 72 hours for full polymerization before final service, regardless of temperature.

Never speed up the cure with artificial heating, as this compromises the final mechanical properties of the anchor.

How do I properly clean the holes before injecting the adhesive?

Professional hole cleaning is the most critical step to ensure maximum anchor strength. Follow this 3-step procedure:

Mechanical brushing:

Use a wire brush equal to or slightly larger than the hole diameter. Insert and remove it with vigorous rotation 5–10 times to loosen laitance, dust, and friable particles on the walls.

Air blowing:

Using a manual pump or oil-free compressor, blow from the bottom upward for at least 10 seconds. Repeat until no dust exits the hole.

Re-brushing and final blowing:

Repeat a light brushing followed by a final blow to remove debris loosened during the first brushing.

Final visual inspection: the hole must appear clean with sound concrete exposed on all walls. For water-saturated holes, perform cleaning before filling.

Never use solvents, oils, or pressurized water—they contaminate concrete pores and reduce chemical adhesion.

Does the AC200+ system withstand Quebec climate and freeze-thaw cycles?

Absolutely. AC200+ has been rigorously evaluated and certified specifically for performance under repeated freeze-thaw cycles in accordance with applicable ASTM standards. This certification ensures your anchors maintain structural integrity despite the extreme temperature variations typical of Quebec.

Climate-specific advantages:

  • Continuous service range: -40°C to 80°C ensures performance during the harshest Quebec winters and summer heat waves.
  • Winter installation: Unique ability to install down to -10°C eliminates seasonal jobsite shutdowns unlike standard epoxy.
  • Outdoor durability: Formulation withstands daily freeze-at-night/thaw-by-day cycles during Quebec’s spring and fall, which quickly degrade non-certified systems.
  • Marine applications: Approved for structures exposed to saltwater, ice, and severe humidity conditions.

To ensure maximum performance, always follow recommended installation procedures including meticulous hole cleaning and proper curing time based on temperature. Complete technical documentation is available for structural inspections and code compliance.